Photonics, the science of light, has already revolutionized some medical fields such as ophthalmology. With attractive pricing and low maintenance cost versus YAG lasers, lasers based on optical fiber are rapidly being adopted in the biomedical field as they also offer minimally invasive and highly precise solutions.
Exail optical components such as doped fibers and FBGs laser mirrors provide high-efficiency, high-power output and robustness over time. With its extensive experience and large portfolio, Exail can support the emergence of innovations in this field, in particular:
urology with thulium and/or holmium doped fibers for 2 µm emission,
medical imaging applications with neodymium-doped fiber emitting at 920 nm.
Fiber laser in the 2 µm range for urology
Fiber lasers in the 2 µm range are drawing the attention of medical laser manufacturers as they are “eye-safe”, meaning that our eye is sensitive to such a large wavelength and instinctively closes itself when touched. That is not the case with laser thinner than 1,4 µm that can reach deep inside our eyes and damage it irreversibly.
An interest is especially rising for thulium (Tm) doped fibers for the development of lasers for ureteroscopy, ureteric and kidney stone management. Exail has developed a fiber laser cavity (a thulium doped fiber and fiber Bragg gratings – FBG), for this innovative laser technology that may become an important milestone for kidney stone treatment.
The goal is to be minimally invasive without breaking the skin barrier. The thulium fiber laser has several advantages over the holmium YAG laser, traditionally used in urology. With a wavelength of 1940 nm, the absorption coefficient of thulium fiber laser is four times greater in water leading to outstanding tissue ablation rate (1940 nm matches the near-infrared absorption peak of liquid water at room temperature), and it enables much smaller spot sizes to be created with less powerful pulses but at a much higher rate. Thus it allows a precise and respectful surgical approach to the other bodily functions. It is also a versatile technology, minimizing blood losses during surgical operation thanks to a “mix” of cutting and coagulation.
Tm fiber laser has average and peak powers of 100 W and it does not burst tissues, providing clean and precise cutting. It allows for pulse prolongation up to 12 ms, with regular pulses. Therefore, the power produced by the laser has a constant peak, called the super pulse creation. It is perfect for surgical applications, providing even greater precision and less collateral damage. The Tm-fiber laser technology has shown excellent results during lab testing on synthetic kidney, and it has been introduced as a new revolutionary tool for other types of surgery, including thoracic & pulmonary surgery and endoscopic surgery.
The doped fibers in the Exail portfolio especially address the range of 1900 to 2090 nm (i.e 1940 nm for urology), with different absorption wavelengths available for the FBGs that can be incorporated to any kind of fiber. Exail can produce custom fibers based on core co-doped with thulium (Tm), holmium (Ho), or both (Tm/Ho), with on demand customization: any core size (4 to 25 µm), one-two or three claddings, any kind of coating and any kind of doping level.
Lasers in the 1,5 µm range for tattoo removal and other skin treatments
Different new technologies of fiber lasers are being developed for application in the dermato-aesthetics field for tattoo removal:
One of them is based on a picosecond laser that delivers bursts of ultrashort pulses for tattoo removal, with enhanced efficiency and higher patient tolerance than with larger (sub-nanosecond) laser that present higher peaks of temperature. Such multi-pulse fiber lasers are available in the 1064 nm (532 when doubled) and the 1550 nm range (775 when doubled).
Another medical device for tattoo removal is a laser system based on erbium (Er) doped fiber, which emits in the 1550 nm range. The technique consists in heating very quickly a specific target of the dermis (fibroblasts for example), while limiting the heating of the dermis or the epidermis itself, by creating coagulation micro-wells with the photothermolysis principle. It allows to act in depth and to limit the thermal diffusion.
Exail masters the fabrication of the key components necessary for a pulse fiber laser cavity in the 1,5 µm range:
Powering multi-photon microscopy with neodymium (Nd) doped fiber lasers
Bio or medical imaging relies on the ability to image, in real-time and with ultimate high-resolution, living biological materials (i.e cellular tissues at depths of about one millimeter), while being totally non-invasive. Laser sources are used in a technique called “two-photon fluorescence excitation microscopy”. It requires ultrafast pulsed lasers capable of producing high peak power with low pulse energy to avoid degradation of living cells. Fiber based lasers are ideal solutions for this application. They are much easier to install and to maintain than solid state lasers.
Following over a decade of fruitful research collaboration (with the team of Mathieu Laroche at the CIMAP lab), Exail could develop a neodymium (Nd)-doped fiber enabling the design of a laser source for emission in this 920 nm region. Exail’s portfolio now counts the sole industrial reference of Nd-doped fibers perfectly adapted to multi-photon microscopy: